Well-known for its efficiency and thin profile, Kooltherm pipe insulation suits use for HVAC and building services in range of sectors, including residential, commercial, institutional, industrial, and leisure. It can be utilised in new build and renovation projects, while also being a cost-effective option with high performance in insulation efficiency, fire resistance, low smoke emission, and compressive strength.
The dense cross-linked structure of this insulation is difficult to ignite. It also creates a durable carbonaceous layer on its exterior when subject to fire, which helps to lower heat generation and prevent further flames from spreading. Kooltherm pipe insulation has a best-in-class European Reaction to Fire performance of BL,s1,d0 and is FM approved in accordance with the Approval Standard Class 4924, supplying it with exceptional fire and smoke performance characteristics that make it compatible with its intended applications.
Features & Benefits: Kooltherm Phenolic Pipe Insulation Lagging – 108mm x 25mm x 1m
- Suits use for HVAC and building services in range of sectors
- Supplies benefits for specifying engineers, M&E contractors, building service and facilities managers, property developers, and building owners
- Length of 1m
- Pipe size of 108mm
- 25mm wall thickness
- 0.025 W/mK thermal conductivity
- Can be utilised in new build and renovation projects
- Non-fibrous, rigid thermoset modified resin insulants
- Free of CFC and HCFC
- Excellent fire and smoke performance characteristics
In addition to thermal conductivities which are as low as 0.025 W/mK, Kooltherm Pipe Insulation systems and products are crafted using a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP). Based on panted technology, these non-fibrous, rigid thermoset modified resin insulants do not contain any CFC or HCFC.
KIWA N.V. Technical Assessment Body has tested and certified the performance, application techniques, and factory production control of Kooltherm Pipe Insulation. Use is covered by the KIWA BDA Agrement certificate BAP 15-036/01/C and by LABC Warranty. Performance has also undergone assessment by Local Authority Building Control and is covered by the LABC Registered Detail RD certificate number EWW382.
Standards & Certification
- KIWA BDA Agrément: certificate BAP 15-036/01/C
- Spread of flame: Class 1 to BS 476-7
- Thermal conductivity: 0.025W/mK at 10°C, mean declared in accordance with EN14314
- FM Approved: Approval Standard Class 4924
- LABC Registered Detail RD: certificate number EWW382
- European Reaction to Fire: BL,s1, d0 to EN 13501-1